System Air Conditioner Piping & Unit Combination Quote Check

Count shared pipe segments once and check group lengths, fittings and additional refrigerant.
Record installer-confirmed combinations, routing and missing work using tax-inclusive KRW quotes.

Check one outdoor-unit circuit by counting each physical segment once. Ask the installer to confirm the exact domestic model combination, pipe sizes, fittings and refrigerant rule. All amounts are tax-inclusive KRW; pipe prices are per metre of a liquid/gas pair.

Blank prices mean unknown. Enter zero only after confirming inclusion or no charge.

1. Units and confirmation documents

Indoor unit 1

2. Pipe groups, allowances and prices

Pipe prices use pair-metres; refrigerant coefficients use actual liquid-pipe metres. Free billed-length allowances do not reduce refrigerant length.

Pipe group 1

3. Physical pipe segments

Enter a shared segment once with one ID. OUT is the outdoor root, J can name a junction and I1 an indoor endpoint. Indoor paths list segment IDs in order.

Segment 1

4. Branch fittings / headers

For each junction with multiple outlets, enter the installer-confirmed fitting model and quantity. Fitting counts are not inferred from indoor-unit counts. Confirm whether the price covers a liquid/gas set.

5. Confirmed additional-refrigerant rule

Use the weighted expression only when it matches the exact model worksheet. Otherwise enter the installer-confirmed extra mass manually. Clamp the final mass at zero, round up to whole grams, then round cost to whole KRW.

6. Base work, extras and final confirmation

Complete valid inputs and routes to see the check

  • Required value, unit or range: Outdoor model
  • Check the value, unit and allowed range
  • Required value, unit or range: Indoor unit / 1 / Model
  • Required value, unit or range: Pipe group / 1 / Pair sizes
  • Required value, unit or range: Extra work / 1 / Item name

Check the equipment list and physical piping behind a system AC quote

The number of indoor units alone does not establish the required pipe and fittings for a multiroom system air conditioner.
One quote can combine a shared main pipe, separate room branches and several diameter groups.
Adding every indoor-unit route length can count the shared main several times, while checking only a basic installation fee can miss branch fittings and additional refrigerant.

This calculator checks one outdoor-unit refrigerant circuit using the combination and physical routes confirmed by your installer.
It totals unique pipe segments once, subtracts the quoted allowance within each diameter group, checks fittings and refrigerant charges, and identifies work missing from the quote.
Use the report when reviewing a family member’s installation or requesting a revised written quote.
Amounts are tax-inclusive KRW; manufacturer references concern model-specific documentation for equipment supplied in South Korea, reviewed for the 2026 project year.

Enter prices and refrigerant coefficients from the actual written documents.
The example is fictional arithmetic, not a market average or an official manufacturer tariff.
A result or confirmation checkbox does not constitute refrigerant-system design, installation approval, safety approval or a performance guarantee.

Record the indoor/outdoor combination and its documentary evidence

One outdoor unit and an indoor-unit list

Enter the outdoor unit’s complete model and rated capacity, then give every indoor unit its own row.
Up to 16 indoor-unit rows are supported.
Use a distinct endpoint ID for each unit, including identical models in different rooms, because their physical pipe routes end at different places.
Calculate separate outdoor-unit circuits separately rather than mixing their independent piping in one graph.

Pending, confirmed and rejected combinations

Mark the combination confirmed only after the installer has checked the relevant domestic model documentation and configuration.
Record an identifiable manual title, revision, combination table or written response.
Leave an unresolved combination pending, and retain rejected status if the installer says the proposed combination cannot be used.
The connected indoor capacity and outdoor-capacity ratio are arithmetic references; neither is an automatic compatibility threshold.

Changing one unit or a model suffix can invalidate an earlier confirmation.
The refrigerant type, electrical and communication configuration, and product generation require the appropriate manufacturer documentation and installer review.
Existing-pipe reuse also needs a site and model check.
Do not remove lengths or supplementary work merely because some piping might be reused.

Enter a shared physical segment once and reference it in each route

Use OUT as the outdoor-unit root, J as an example junction and I1 as an example indoor endpoint.
Give each physical segment a unique ID such as S1 or S2, with its start node, end node, diameter group and measured length.
For every indoor unit, list the segment IDs in their travel order from OUT to that unit.
Several routes can reference S1, but its physical quantity is counted once.

Three rooms sharing a main pipe

Suppose S1 runs 10m from OUT to J, S2 runs 4m from J to I1, S3 runs 6m to I2, and S4 runs 5m to I3.
The indoor routes are S1→S2, S1→S3 and S1→S4, with lengths of 14m, 16m and 15m.
Adding them gives 45m and counts S1 three times.
The unique physical pipe-pair length is 10+4+6+5=25m, with S1 identified as the shared segment.

Recreating the same physical segment under a second name is also duplication.
Review repeated start/end pairs, disconnected routes, missing segment references, incorrect indoor endpoints, cycles and merging paths.
A segment unused by all indoor routes must also be resolved.
This graph measures physical quote quantities and does not replace manufacturer checks for design-equivalent length, maximum route length or elevation differences.

Keep pipe-pair metres, diameter groups and quoted allowances distinct

A diameter group combines a specified liquid/gas pipe pair and the same quoted charging basis.
Create up to eight groups and transcribe the actual diameter descriptions from the quote.
One metre means one metre of route carrying the liquid/gas pipe pair.
Do not combine a pair-metre price with the sum of two individual pipe lengths.
If a supplier prices individual pipes, ask for a consistent pair-route basis before entering the quote.

Chargeable length within each group

Chargeable pipe-pair metres = max(unique physical group metres − that group’s included metres, 0)
Pipe charge = chargeable metres × tax-inclusive KRW/m, rounded to a whole won
Subtract an allowance once within its own group.
Do not transfer an unused allowance to another diameter group.
If an allowance exceeds the physical group length, the confirmed total is withheld until the quote’s charging basis is clarified.

Enter physical lengths to one decimal place and check that a shared segment has not been assigned to multiple groups.
Do not allocate an unspecified allowance to the most expensive diameter group without supplier confirmation.
Each segment’s quote-inclusion status records whether the supplier’s quantity schedule covers that actual segment.
A known length and price can produce a calculable subtotal even when a segment is missing from the quote; request a revision before treating that amount as confirmed.

Use confirmed fitting models and quantities

Record the installer-confirmed fitting model and quantity at each point where shared piping divides toward several indoor units.
Check that every junction with multiple outgoing branches has a corresponding fitting row and is covered by the quote.
The calculator does not choose a Y branch or header from the number of outlets.
Indoor-unit count minus one is not treated as a universal fitting rule.

Enter the quoted product or fitting model, its confirmed whole-number quantity and tax-inclusive price per item.
Establish whether liquid and gas fittings are one set or separate quoted items.
Do not enter the same set price twice, or multiply a price covering several fittings by their quantity again.
A missing junction row or an unquoted required fitting prevents a confirmed total.
Record unrelated accessory work separately under additional site work.

Calculate refrigerant separately from the pipe-price allowance

Confirm the additional-refrigerant rule in the domestic model’s manual and the installer’s calculation sheet.
Liquid-pipe diameter coefficients, indoor-unit corrections and manufacturer included allowances can be model-specific.
A contract including 5m of pipe installation does not establish a 5m refrigerant deduction.
Do not add gas-pipe length to a liquid-pipe coefficient or deduct free installation metres from the refrigerant basis.

Unknown, included and manual methods

Leave the method unknown until the rule has been established.
Choose included only when the written quote confirms that the required additional refrigerant is covered.
Use manual grams when the installer has confirmed the additional mass or the model’s formula differs from the weighted expression offered here.
Record the source and confirmation, and use a tax-inclusive KRW/kg price for a separately charged amount.

Confirmed weighted method

Additional g = max(sum of actual liquid-pipe metres × group g/m + indoor correction g − manufacturer included-equivalent g, 0)
Round a positive final mass up to a whole gram.
Refrigerant charge = additional g÷1,000×KRW/kg, rounded to a whole won.
Use this expression only when it matches the confirmed model-specific calculation.
Do not confuse the included-equivalent allowance or indoor correction with factory charge or rated indoor capacity.

Do not transplant foreign-manual coefficients or connection limits into domestic-model defaults.
Recheck coefficients when the refrigerant, model or manual revision changes.
A missing coefficient is not automatically zero.
An unknown rule or price leaves the refrigerant charge and confirmed total unresolved.
The calculator does not select a refrigerant or instruct the user how to charge it or perform installation safety procedures.

Reconcile base work, additional site work and tax-inclusive amounts

Enter the base-work charge once for this circuit’s whole job.
List additional drilling, electrical work, drainage, equipment access or work at height with the whole-job amount for each item.
These amounts are not automatically multiplied by the indoor-unit count.
Avoid duplicating charges already included elsewhere.
The outdoor unit’s location does not generate an assumed surcharge percentage or standard fee.

Use tax-inclusive prices consistently; VAT is not added again.
A blank amount is unknown, whereas zero means the charge is confirmed included or unnecessary.
Entering zero merely to obtain a total hides the omission you are trying to identify.
Keep a quote number, supplier/version identifier and actual confirmation date so the report identifies the written conditions checked.
The overall scope confirmation does not discover work omitted from your own input list: identify the required site work before confirming it.

Fictional three-room example: 25m of unique piping and KRW 620,000

These figures are arithmetic assumptions, not official prices or recommended refrigerant quantities.
Assign the shared 10m S1 to group A and the 4m, 6m and 5m room branches to group B.
Assume A includes 5m at KRW 20,000/m, while B includes 3m at KRW 15,000/m.
After deduplication and the group allowances, the chargeable lengths are 5m for A and 12m for B.

Pipe, fittings and work

Group A: 5m × KRW 20,000 = KRW 100,000
Group B: 12m × KRW 15,000 = KRW 180,000
Confirmed fitting at J: 1 × KRW 80,000 = KRW 80,000
Base work: KRW 200,000
Whole-job drilling: KRW 30,000
Subtotal before additional refrigerant: KRW 590,000

Additional refrigerant and total

Assume 20g/m for A, 10g/m for B, a 50g indoor correction and a 100g manufacturer included-equivalent allowance.
10×20 + 15×10 + 50 − 100 = 300g.
At KRW 100,000/kg, 300÷1,000×100,000 = KRW 30,000.
The calculable subtotal is 590,000+30,000 = KRW 620,000.

Refrigerant uses the physical 10m and 15m liquid-pipe lengths, not the chargeable 5m and 12m lengths.
A manually confirmed 301g at the same kg price would cost KRW 30,100.
Loading the example does not confirm your equipment or site.
A confirmed total requires all necessary segments and fittings to be quoted, with prices, refrigerant rules, combination, site routes, quote identity, date and whole-job scope confirmed.

From source documents to an installer handoff

  1. Prepare documents: collect the model list, domestic-model combination evidence, route drawing, diameter-group prices and refrigerant calculation sheet.
    Leave unavailable information pending.
  2. Enter the circuit and routes: connect unique segments from OUT to each indoor endpoint.
    Enter measured lengths and resolve disconnected or unused segments first.
  3. Reconcile quantities and prices: match pipe-pair metres, group allowances and fitting item/set units.
    Enter the confirmed refrigerant method and additional site-work amounts.
  4. Review confirmations: record the combination source, site-route confirmation, quote identifier and date.
    Ask the supplier to correct missing segments and unknown amounts in writing.
  5. Save a record: download the TXT report or print it and save as PDF.
    Distinguish quote versions and confirmation dates before replacing an earlier report, then check the revised quote again.

Editing values clears the overall quote confirmation, so review the changed conditions again.
Do not carry an earlier equipment or site confirmation forward after changing the models or routes.
Include the unresolved-item list with a saved report so a recipient does not mistake a subtotal for a final contract amount.

Interpret subtotals and use the report in real quote discussions

Reviewing installation for a parent’s home

If only a total was quoted by phone, request the room-by-room equipment list and pipe route first.
Check that a main shared by several rooms is counted once in physical quantities.
Ask explicitly whether fittings, electrical work and drainage are included.
Preserve unknown items rather than replacing them with zero before sharing the report with family.

Comparing quotes before and after a site visit

Separate changes in segment length, diameter groups and additional site work when a post-visit quote changes.
Establish that both quotes concern the same models and site conditions before comparing prices.
If actual piping changes, have the refrigerant calculation checked again.
Do not apply an earlier allowance automatically to revised quantities.

The known-price subtotal is the sum calculable from the current inputs.
It is not an upper bound covering all omitted work or a promise that no further charge will arise.
Pipe sizing, maximum route lengths, elevation, installation methods, leak checks, electrical protection and drainage suitability require the relevant professional review.
Do not try to resolve a rejected combination or a site problem by changing prices; request an alternative configuration and a new quote.

Frequently asked questions

Can I add all indoor-unit route lengths?

Those lengths describe each route, but shared segments can occur several times.
Use the unique physical segment total for quote quantities.

Should I price the liquid and gas pipes separately?

This calculator uses KRW per metre of a liquid/gas pipe pair along one route.
Reconcile individual-pipe or summed-pipe pricing with the supplier before entering it.

Is the fitting count always indoor units minus one?

No automatic rule is applied.
Ask the installer to confirm the actual branch arrangement, appropriate model and item or set quantities.

Does included pipe length reduce refrigerant length?

The quoted installation allowance applies only to the pipe charge.
Calculate refrigerant separately from actual liquid-pipe lengths and the confirmed model rule.

What if the manufacturer uses another refrigerant formula?

Use the manually confirmed additional grams.
Record the source calculation instead of inventing coefficients to approximate the answer.

How do zero and unknown differ?

Zero is a confirmed included or unnecessary charge.
Leave an unestablished price or inclusion blank; the confirmed total remains withheld.

Does a low connected-capacity ratio prove compatibility?

No.
The ratio is an arithmetic reference and does not establish compliance with model, communication, refrigerant or site conditions.

What are TXT and printed reports for?

They communicate the quote version, confirmation date, quantities and unresolved items to family or the installer.
They do not replace a contract or manufacturer installation approval.

Official references and review date

References were checked on November 18, 2026.
This tool checks arithmetic from actual written quotes and the relevant domestic-model documents; it supplies no fixed market prices or statutory tariff.
Recheck the models, refrigerant type, pipe diameters, correction and allowance rules, site scope and confirmation date when products or manual revisions change.

  • LG Electronics MNQ0720C2S installation FAQ: supports the need for a site inspection and model-combination and existing-pipe checks.
    This individual product guide is not a universal system-AC compatibility table.
  • LG MULTI V S official technical data, Brazil edition, May 2023: indexed Chapter 7 piping and additional-refrigerant text was reviewed as a structural reference.
    Full PDF access was restricted; foreign-model values and coefficients are not applied to domestic products.
    Design-equivalent lengths must also be distinguished from physical quote quantities.

Request a revised quote for the unresolved items

Review unique pipe length and group charging quantities, then check fittings, refrigerant evidence and missing site work.
Save a report with unresolved items and obtain a written reply for the same circuit and equipment before checking the quote again.
For a broader comparison including removal, transport and replacement equipment, use the air conditioner relocation cost calculator to organize those separate costs.