Compare the electricity ledger before approving a leak repair
This air compressor load, unload, and leak repair payback calculator compares energy recorded before and after a repair with the money needed to carry it out.
Workshop owners and maintenance staff can check electricity savings, the change in annual service costs, and how many months of positive net benefit would recover the initial cost.
A reduction in leaking airflow is not automatically the same percentage reduction in electricity use, so the tool does not convert a leak percentage into energy savings.
Prepare meter records, loaded and unloaded running hours, representative production output, supply pressure, and the repair quote.
Begin with the number of observed days before repair and the total hours covered, then enter the after-repair record on the same basis.
If work has not yet been done, identify a supplier-confirmed after-repair assumption as a scenario.
A scenario calculation is not a measured verification of actual savings.
The decision this supports
Read before-and-after annual kWh and energy costs alongside annual net benefit and initial cost.
If matching operating conditions have not been established, collect the missing operating intervals or production evidence before approving the work.
Save or print the result and checklist to discuss the supplier’s savings assumptions and repair scope.
Amounts use KRW as a currency label; the tool supplies no national tariff or exchange-rate conversion.
Loaded, unloaded, and stopped or standby states are different
Loaded operation
Enter actual average electrical input in kW and hours for the air-producing interval.
Motor nameplate shaft output and advertised ratings are not necessarily average electrical consumption.
Use measurements matching working pressure and the actual control state.
Unloaded operation
A running compressor can still consume power while producing little or no useful compressed air.
Treating unloaded hours as stopped hours at 0 kW distorts the comparison.
Enter separately confirmed average input power.
Stopped or standby
Controls, fans, and auxiliaries may remain inside the metered boundary when the main motor stops.
Enter 0 only when zero consumption has actually been confirmed.
Leave an unknown power input blank rather than assuming zero.
Do not compare a before value covering both compressor and dryer with an after value covering only the compressor.
For VSD or continuously modulated operation that cannot be represented adequately by three average intervals, use directly metered kWh.
The tool does not predict a control-specific performance curve or recommend a pressure setting.
Define observed days and the hours actually covered
Observed days are the number of operating days represented by the entered energy record, entered as a whole number from 1 to 366.
Total observed hours cover every interval inside that measurement period and boundary.
They must be greater than 0 and no more than observed days × 24 hours.
Three observed operating days of 8 hours each therefore mean 3 days and 24 total hours.
Do not automatically add 48 unrecorded overnight hours just because three calendar days passed.
Different observation lengths
A before record of 1 day and an after record of 3 days can be compared per representative operating day when their daily coverage matches.
Before: 1 day and 8 hours; after: 3 days and 24 hours both cover 8 hours per day.
Before: 1 day and 8 hours; after: 1 day and 6 hours do not match, so the savings comparison is held.
Dividing by days does not itself correct production, pressure, or temperature differences; matching conditions still require separate confirmation.
Record the meter file, measurement location, product and output quantity, pressure, temperature, and control settings in the period and evidence notes.
A record restricted to normal shifts has a different boundary from one including holidays and non-production leakage.
A short unrepresentative interval cannot establish a year’s savings by itself.
Choose observation coverage that represents the production cycles that actually repeat.
Choose mode totals or direct kWh, without adding both
Measured power and hours by mode
Period energy = loaded kW × h + unloaded kW × h + stopped/standby kW × h
All intervals belong inside the observation period, and their hours must sum to total observed hours before complete period energy is available.
A shorter sum leaves an unconfirmed interval rather than automatically assigning it 0 kW.
A longer sum requires correction of overlapping or incorrect hours.
Direct meter kWh
Enter the meter’s confirmed energy for the complete observation period and the same equipment boundary.
kWh already integrates power over time, so do not multiply it by observed hours again.
Selecting direct input excludes the preserved mode totals from the calculation.
When switching methods, check the retained ledger and remember that only the selected method contributes to results.
A mode with confirmed 0 hours has 0 energy and does not require a kW value.
An empty time field does not establish that the mode never occurred.
Positive hours without confirmed kW cannot establish that interval’s energy.
A known subtotal during partial input sums only confirmed intervals; it is not complete observation-period consumption or verified energy savings.
Match annual operating days and the electricity-rate boundary
Annual days under the same conditions describe how often the representative operating day repeats in a year, entered as a whole number from 0 to 366.
Allow for holidays, regular closures, seasonal work, and planned production outages.
Observed days divide the measurement record, while annual operating days count repetitions for the budget.
They need not be equal.
Save separate calculations for seasons or shifts with substantially different operating patterns.
Confirmed variable rate in KRW/kWh
Enter the variable electricity rate verified from your bill or contract, together with a note explaining its coverage.
No Korean statutory tariff or specific electricity plan is built in.
Base charges, maximum demand, power-factor adjustments, time-of-use bands, tiers, and taxes are not independently reproduced.
If the entered rate already includes tax or adjustments, document that coverage and avoid adding the same amount again.
Check whether dividing an entire facility’s bill by compressor kWh represents the actual incremental cost of another compressor kWh.
An average containing unrelated equipment and fixed charges can exaggerate realizable cash savings.
The same rate is applied to both records, separating the entered energy difference from a bill change caused only by a rate change.
Separate initial work from recurring maintenance
Normalize the initial repair cost to the actual quoted total including parts, labor, travel, and tax on a consistent basis.
Additional measurement and one-time downtime costs include only amounts not already covered by that total.
If the repair package includes measurement, enter a confirmed additional measurement cost of 0 to avoid double counting.
If downtime loss is estimated, record its evidence and distinguish that assumption from an actual payment.
One-time initial cost
Initial total = repair + additional measurement + one-time downtime
Leave an unknown amount blank.
A missing item leaves the known cost available for reference but prevents a completed payback calculation.
No automatic VAT percentage or contractual billing increment is applied.
Recurring annual service
Enter annual maintenance before and after repair separately.
An increase reduces electricity savings to net benefit, while a decrease contributes to net benefit.
Check the period to avoid counting the initial repair again as annual service or treating the whole existing maintenance bill as a new expense.
Energy, net benefit, and simple payback formulas
Annualize the measured period
Daily kWh = period kWh ÷ observed days
Annual kWh = daily kWh × annual days under the same conditions
Annual electricity cost = annual kWh × common variable rate
Energy cost and net benefit
Annual electricity savings = (before annual kWh − after annual kWh) × rate
Annual net benefit = annual electricity savings − (after annual maintenance − before annual maintenance)
Monthly average net benefit = annual net benefit ÷ 12
Payback with positive benefit
Simple payback months = initial total ÷ annual net benefit × 12
A zero or negative annual net benefit does not produce a finite recovery period.
A positive net benefit and confirmed initial total of 0 produce 0 months.
Missing evidence that holds the calculation is distinct from zero benefit or non-recovery.
The monthly average divides the annual estimate by 12; it is not a promise of an identical reduction on every monthly bill.
Intermediate values remain unrounded, final currency displays round to whole KRW, and payback displays one decimal place.
This simple screening measure differs from NPV or IRR incorporating discount rates, financing, equipment life, renewed leakage, and the timing of replacement work.
Worked example: KRW 600,000 initial cost and 18 months
This fictional example checks the arithmetic; it is not a market quote, standard compressor performance, or guaranteed saving.
Assume 1 observed day and 8 hours before and after, with the same production, pressure, temperature, and metered equipment.
Loaded input is 10 kW, unloaded input is 3 kW, and standby input is 0.5 kW.
Before hours are 5, 2, and 1 respectively; after hours are 4, 1, and 3.
Energy and electricity costs
Before: 10 × 5 + 3 × 2 + 0.5 × 1 = 56.5 kWh
After: 10 × 4 + 3 × 1 + 0.5 × 3 = 44.5 kWh
Assume 250 days/year and KRW 150/kWh
Before: 14,125 kWh · KRW 2,118,750
After: 11,125 kWh · KRW 1,668,750
Savings: 3,000 kWh · KRW 450,000/year
Maintenance and recovery
Before maintenance: KRW 100,000/year
After maintenance: KRW 150,000/year
Annual net: 450,000 − 50,000 = KRW 400,000
Monthly average: approximately KRW 33,333
Initial: 500,000 + 50,000 + 50,000 = KRW 600,000
Payback: 600,000 ÷ 400,000 × 12 = 18 months
Do not value the repair using only the reduction from 2 unloaded hours to 1.
Loaded and standby hours also change, so all three intervals must be totaled inside the same 8-hour boundary.
Omitting the KRW 50,000 maintenance increase confuses KRW 450,000 electricity savings with KRW 400,000 annual net benefit.
After exploring the example, restore your original inputs and continue with actual evidence.
Interpret rate and operating-day sensitivity
Sensitivity changes only the electricity rate by −10% and +10%, or only annual operating days by −10% and +10%.
Maintenance, initial cost, and all other conditions remain fixed so the effect of each assumption can be read separately.
The higher operating-day scenario is capped at 366 days.
These scenarios are neither a guaranteed price band nor a statistical prediction interval for savings.
Sensitivity in the fictional example
KRW 135/kWh → annual net benefit KRW 355,000
KRW 165/kWh → annual net benefit KRW 445,000
Keeping KRW 150/kWh and changing only days to 225 or 275 gives the same net-benefit range in this example.
Rate and days are not changed together, and the annual maintenance difference remains KRW 50,000.
Even if energy consumption increases, a sufficiently large maintenance reduction can make net benefit positive.
Read the energy difference and net benefit side by side.
Input sequence and the next step when evidence is missing
- Enter before-repair observed days and hours, then choose mode totals or direct kWh to match your evidence.
- Switch to the after tab and enter its ledger, identifying each record as measured or a scenario.
- Compare period notes, production, pressure, temperature, and the metered boundary, then confirm whether conditions match.
- Enter annual days, variable rate and coverage, annual maintenance on both sides, repair, additional measurement, and downtime costs.
- Distinguish known subtotals from held values, then read the available annual kWh, costs, net benefit, and payback.
- Save or print the leak-measurement and repair-scope notes with the checklist, and ask the supplier for missing evidence.
A blank is unknown; 0 is an explicit confirmation that the item has no cost or consumption.
If daily observation coverage differs or production conditions are unknown or different, individual energy values can still be available while savings and payback remain held.
Treat any scenario result as an assumption-based comparison rather than a measured performance verification.
Use Edit inputs to return to the ledger and correct missing values while keeping values on the other tab.
Frequently asked questions
Does a 20% reduction in leakage mean a 20% electricity saving?
No common percentage can be assumed.
Energy response depends on compressor control and the change in unloaded operation.
Compare actual before-and-after kWh or measured mode power and hours.
Can I enter unloaded power as 0?
Only if zero consumption has actually been measured.
A motor running unloaded can still consume electricity, and an unknown value should remain blank.
What if mode hours total less than observed hours?
The remaining interval is not assigned 0 kW.
Confirm the missing state and power, or enter directly metered kWh for the full observation period, before treating the period energy as complete.
Can before and after observations have different day counts?
They can be normalized to daily kWh when they represent matching operating days and hours per day.
Production, pressure, temperature, and the metered boundary still require separate confirmation.
Are direct kWh and mode kWh added together?
Only the selected method is used.
Direct kWh already measures energy for the period, so mode totals are not added and hours are not multiplied into it again.
What payback is shown with zero or negative net benefit?
A finite recovery period is not shown without positive net benefit.
This differs from a calculation held because inputs are missing, and is a reason to review costs, operation, and energy assumptions.
What if measurement is included in the repair quote?
Enter the inclusive total as repair cost and confirm additional measurement cost as 0.
Avoid counting the same expense twice, and distinguish recurring annual maintenance from one-time initial work.
Does a short payback mean I should approve the work immediately?
It is simple payback under entered assumptions, without a performance, safety, or contract guarantee.
Confirm repair scope, metering conditions, renewed-leakage risk, and excluded costs with the supplier before deciding.
Primary sources and update basis
- NRCan Energy Efficiency Reference Guide Compressed Air: controls, leaks, and baseline sections support distinguishing unloaded power and actual operating conditions.
The page modification date is 2025-01-14.
- DOE/NREL Compressed Air Evaluation Protocol: NREL/SR-7A40-63210, 2014-11, printed page 8 equations 6 and 7 and pages 10–11, 15–19, and 23–25 inform interval power and hours, representative cycles, matching conditions, and the distinction between idle and shutdown.
- DOE Improving Compressed Air System Performance: second edition, 2003-11, printed pages 71–72 inform the simple-payback principle.
Sources were checked and the calculator design established on 2026-11-25.
Old example prices and control-specific savings ratios are not reused as current rates or universal performance factors.
No statutory tariff, tax percentage, subsidy, or safety-design decision is supplied.
Reconfirm measured values, equipment boundaries, rates, and included contract items before each order.
Review source links at least every 6 months and establish a new baseline when equipment or controls change.
Turn the energy ledger into a repair discussion
Start with before-repair observed days and add verified power and hours one interval at a time.
Keep operating-condition notes and leakage evidence with the figures to show which assumptions support the proposed net benefit.
Save before-and-after kWh, maintenance, initial scope, and unresolved items together with payback, then decide whether to request further measurement or proceed with a confirmed repair scope.